Gold Member Since 2016
Audited Supplier
Nanjing Norman Biological Technology Co., Ltd.

Cystatin-C Rapid Test Kits, Cys-C Reagent Kits, Poct Rapid Test Kits manufacturer / supplier in China, offering Quantitative Ivd Rapid Test Kits for Cys-C, Total Triiodothyronine (TT3) Kit (Chemiluminescence Immunoassay), Heart Failure Chemiluminescence Immunoassay Analyzer and so on.

(/ )

Quantitative Ivd Rapid Test Kits for Cys-C

FOB Price: Get Latest Price
Min. Order: 1,000 Pieces
Port: Nanjing, China
Production Capacity: 1, 000, 000.00/Month
Payment Terms: L/C, T/T, D/P, Western Union, Paypal, Money Gram

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Classification: Biological Diagnostics
  • Certification: CE, ISO13485, RoHS
  • Methodology: Fluorescence Immunoassay
  • Service: International After-Sales
  • Delivery Detail: Depend on Quantity
  • Transport Package: in Carton
  • Origin: Jiangsu, China (Mainland)
  • Type: Biochemistry Analyzer
  • Group: All People
  • Manufacturer: Independent R&D
  • Test Time: 15mins
  • Trademark: NORMAN
  • Specification: 15.5CM*16.5CM*7.5CM
  • HS Code: 3002100009
Product Description

                   Quantitative IVD Rapid Test Kits 

                                    For Cys-C

 

Methodology                                                                                                  

Fluorescence Immunoassay

Product show                                                                                                 

Quantitative Ivd Rapid Test Kits for Cys-C

Quantitative Ivd Rapid Test Kits for Cys-C

Cys-C                                                                                                             

One of optimal indicator to reflect the impaired glomerular filtration function .

Optimal endogenous indicator for GFR evaluation.

Metabolic Characteristics.

Constant production rate. not affected by age, sex and nutritional status.

Freely pass through glomerular filtration, no secretion from tubular.

Completely absorbed in proximal tubule.

Completely degraded after being absorbed, no longer enter the loop.
Product Name                                                                                               

General Name:Cys-C Test Kit(Immunofluorescence)
Package                                                                                                         

Test card: Aluminum foil pouch 1pc/bag, desiccant

Package size: 25pcs/box
Intended use                                                                                                  

The test kit is primarily for the in vitro quantitative determination of Cys-C content in human blood serum. Cys-C is a kind of good endogenous marker which reflects the changes of GFR. The change of Cys-C concentration is not affected by inflammation, infection, tumor and liver function. It doesn't relate to gender, muscle mass, diet, body surface area. Cys-C is used in the assessment of Diabetic nephropathy filtration function early renal injury, the early diagnosis of Hypertensive renal damage, the assessment of the recovery of renal function renal transplant patients, the monitoring of the change of renalpatients with hemodialysis, the assessment of old people's renal function, the diagnosis
of children's renal diseases, the monitoring of renal function in tumor chemotherapy and so on.

Main components                                                                                          

1.Test kit contains: 25 test cards and an IC card

The test card is composed of plastic shell and test strip.

The main components of test strip: Sample pad, bonding pad, nitrocellulose membrane, 

Anti-MIgG, absorbent paper, PVC base plate.

2. Diluents (400μl×25 / 10ml×1 bottle): composed of phosphate, surface active agent, etc. 

PH=7.4±0.2

Materials required (but not provided):

1.Timer

2.Centrifuge tube

3.Pipette

4.Disposable tips

Advantage                                                                                                      

1.High sensitivity:0.2mg/l;

2.High accuracy: 99% correlation with LEAMAN;

3.Wide linear range:0.2-10mg/l;

Storage And Stability                                                                                     

1.The reagent box must be stored from 4 to 30ºC, and the period of validity is 12 months. 
2.The reagent strip must be used within 1 hour once its foil pouch has been opened.
3.Do not use the strip beyond the expiration date printed on the outside of the box.

Specimen Collection and Preparation                                                            

1.The whole blood specimen is suggested to use EDTA as anticoagulant, and the specimen 
  is suggested to be tested within 4hours.
2.Precipitation is not allowed existing in under test blood plasma. If there is precipitation, must do                centrifugal process first. Heat inactivated sample and hemolysis sample should be abandoned.
3.The specimens must be returned to room temperature before testing.

Quality Control                                                                                               

Using immunefluorescence quantitative analyzer and relevant Cys-C detection kit (immune-fluorescence techniques) to test quality control product, repeat 10 times, calculate average and CV. If CV≤15%, the average in the scale of quality control product, then the instrument and reagent performance can meet requirements.

Clinical Significance                                                                                       

1.As the indicator of renal injury, Cys-C is better than creatinine, urea nitrogen, etc. 
2.Sensitivity of Cys-C in serum detecting diabetic and nephropathy is better than micro proteinuria and relevant indicators.
3.Cys-C can distinguish glomerulus and renal tubular disease, it is the optimal indicator of early diabetic and hypertensive nephropathy.

Package & Delivery                                                                                        

Quantitative Ivd Rapid Test Kits for Cys-C

Related Products                                                                                           

Related test kits

Quantitative Ivd Rapid Test Kits for Cys-C

About us                                                                                                        

Nanjing Norman Biological Technology Co., Ltd is dedicated to R&D and manufacturing of automated chemiluminescence system. Founded in 2008, Norman biological has been upholding the idea that R&D shapes future ,and concentration determines success. Ever since the beginning, Norman has been focusing on developing and manufacturing  chemiluminescence and immunofluorescence reagents.
Quantitative Ivd Rapid Test Kits for Cys-C


Norman's manufacture center is located in the Yuhua District and owns an over 2,000m2 GMPapproved clean workshop. The R&D base, which is over 2,000m2 , is located in state-level new Jiangbei district. Now there are over 100 R&D engineers, 40% of which hold a PhD or master's degree.

Agent Wanted                                                                                                

If you are interested in working with us, please feel free to contact. 
Quantitative Ivd Rapid Test Kits for Cys-C

Why us                                                                                                           

Manufacturer and Exporter for nearly 10 years with self R&D Research Center;

Professional After-Sale service with On-site support worldwide; 

CE/ISO13485/TUV/Rohs/SGS Certifications!


OEM and ODM are available !
 

 

Send your message to this supplier
Avatar
Mr. Jason
sales manger
*From:
To: Mr. Jason
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Find Similar Products By Category